Mechanical Specifications Digital Analog
Resolution (
µ
m)
2101 5 5
Grating pitch (
µ
m)
40 20
Scale medium Light transmission through chrome-coated glass
Accuracy (@ 20
°
C)
µ
m,
±
, in any 1000mm
3, 5
Max. slew speed (inches/sec) 40
Force to move reading head (lbs)
0.75
Operating Environment
Temperature
Relative Humidity
0
°
to 40
°
C
25% to 95% (non-condensing)
Storage Environment
Temperature
Humidity
-40
°
to 65
°
C
20% to 95% (non-condensing)
Weight w/ armor cable (lbs) 1.4 + 0.05/in of measuring length
Connecting cable
armored or vinyl
Length = 5, 10, and 15 ft,
Connector: DE-9P or Bendix PTO -GA-10-6P
Max. cable length (ft) 35
Measuring lengths (in) 2 - 120
Reference pulse interval Distance or coded